FIREHAWK FHB10 SMOKE ALARM ADAPTOR PLATE

TO REPLACE FIREANGEL ST620, ST622 and ST750 ALARMS

1. REMOVING THE FIREANGEL ALARM

1.1 Unscrew the Fire Angel alarm off the ceiling bracket.

2. INSTALLING THE ADAPTOR PLATE

2.1 Screw the FireHawk Adaptor Plate onto the existing FireAngel bracket (FireAngel ST620, ST622 and ST750 alarms)

3. INSTALLING THE FIREHAWK FHB10 SMOKE ALARM

3.1 Now mount the FireHawk FHB10 alarm to the Adaptor Plate. To fit the alarm correctly, align the vertical line on the side of the alarm casing with the point halfway between the lug and the pin on the Adaptor Plate, then rotate clockwise until the alarm clicks and locks into position.

3.2 Installation is complete

4. REMOVING THE FIREHAWK ALARM

4.1 To remove the FireHawk alarm later if required, use a pen or small screwdriver to depress the lock tab then rotate the alarm anti-clockwise to release it.

Fireblitz Extinguisher Ltd.
Units 15-17 Manford Industrial Estate,
Manor Road. Erith, Kent DA8 2AJ

Telephone: 01322 342238 

TECHNICAL HELPLINE 0800 008 6568

Text on 07885 831239

Email: customerservices@fireblitz.co.uk

8431 V1.1